Анотація:
The interface of ZERODUR ceramics and thin aluminium film was investigated by Raman and secondary ion mass-spectroscopy techniques. Possible chemical reactions at the interface is briefly analyzed and compared with experimental data. Contributions of amorphous and crystalline phases of ZERODUR to Raman spectra are discussed. Keywords: ZERODUR ceramics, Raman spectra, secondary ion mass-spectroscopy. Manuscript received 19.04.05; accepted for publication 18.05.05.