Characteristics and radiation tolerance of a double-sided microstrip detector with polysilicon biasing resistors

Репозиторій DSpace/Manakin

Показати простий запис статті

dc.contributor.author de Haas, A.P.
dc.contributor.author Kuijer, P.
dc.contributor.author Kulibaba, V.I.
dc.contributor.author Maslov, N.I.
dc.contributor.author Perevertailo, V.L.
dc.contributor.author Ovchinnik, V.D.
dc.contributor.author Potin, S.M.
dc.contributor.author Starodubtsev, A.F.
dc.date.accessioned 2015-05-27T11:50:12Z
dc.date.available 2015-05-27T11:50:12Z
dc.date.issued 2000
dc.identifier.citation Characteristics and radiation tolerance of a double-sided microstrip detector with polysilicon biasing resistors / A.P. de Haas, P. Kuijer, V.I. Kulibaba, N.I. Maslov, V.L. Perevertailo, V.D. Ovchinnik, S.M. Potin, A.F. Starodubtsev // Вопросы атомной науки и техники. — 2000. — № 2. — С. 26-33. — Бібліогр.: 11 назв. — англ. uk_UA
dc.identifier.issn 1562-6016
dc.identifier.other PACS: 29.40.Wk
dc.identifier.uri http://dspace.nbuv.gov.ua/handle/123456789/82264
dc.description.abstract The characteristics and radiation tolerance of a double-sided microstrip detector (DSMD) were studied, and the suitability of the detector to the ALICE experiment requirements was analyzed. The sensitive area of the silicon microstrip detector measures 40x75 mm. The DSMD consists of 750 registering strips on each side. The strip pitch is 100 mm and the strip length is 40 mm. Strips of the p+-side were oriented parallel to the side edge, the n+-strips were placed at 30 mrad stereo angle with respect to p+-strips and were separated by a common p+-stop structure. Both p+- and n+-strips are biased by integrated polysilicon resistors with a resistance no less than 10 MOhm. The data readout is realized with use of 120 pF coupling capacitors. The radiation tolerance of the microstrip detector was studied using 20 MeV electrons. The leakage current increases from 2 up to 5 nA per one strip and the interstrip resistance decreases from 43 down to 30 GOhm after 10 krad irradiation dose. The other DSMD features remain unchanged under irradiation. To evaluate the detector efficiency, the yield of good coupling capacitors and biasing resistors, as well as strip leakage currents, interstrip resistance and interstrip capacitance were studied. Based on the data obtained, the number of defective strips is found not to exceed 3%; this provides the required detector efficiency of about 97%. uk_UA
dc.description.sponsorship The authors are very thankful to many colleagues for the valuable discussions and constructive remarks, especially P. Giubellino and O. Runolfsson. This work was supported by INTAS under the Grant 96-0678. uk_UA
dc.language.iso en uk_UA
dc.publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України uk_UA
dc.relation.ispartof Вопросы атомной науки и техники
dc.subject Experimental methods uk_UA
dc.title Characteristics and radiation tolerance of a double-sided microstrip detector with polysilicon biasing resistors uk_UA
dc.title.alternative Характеристики и радиационная стойкость двустороннего микрострипового детектора с поликремниевыми резисторами смещения uk_UA
dc.type Article uk_UA
dc.status published earlier uk_UA