dc.contributor.author |
Болюх, В.Ф. |
|
dc.contributor.author |
Кочерга, А.И. |
|
dc.contributor.author |
Щукин, И.С. |
|
dc.date.accessioned |
2019-02-15T11:05:07Z |
|
dc.date.available |
2019-02-15T11:05:07Z |
|
dc.date.issued |
2018 |
|
dc.identifier.citation |
Исследование линейного импульсно-индукционного электромеханического преобразователя при различных схемах питания индуктора / В.Ф. Болюх, А.И. Кочерга, И.С. Щукин // Електротехніка і електромеханіка. — 2018. — № 1. — С. 21-28. — Бібліогр.: 12 назв. — рос. |
uk_UA |
dc.identifier.issn |
2074-272X |
|
dc.identifier.other |
DOI: https://doi.org/10.20998/2074-272X.2018.1.03 |
|
dc.identifier.uri |
http://dspace.nbuv.gov.ua/handle/123456789/147632 |
|
dc.description.abstract |
На основе разработанной цепной математической модели получены рекуррентные соотношения для расчета взаимосвязанных электромагнитных, механических и тепловых параметров линейного импульсно-индукционного электромеханического преобразователя (ЛИИЭП). Показано, что электромеханические показатели ЛИИЭП со схемой питания индуктора, формирующей апериодический токовый импульс возбуждения, лучше, чем у ЛИИЭП с возбуждением
индуктора однополярным токовым импульсом, но хуже, чем у ЛИИЭП с возбуждением индуктора колебательнозатухающим токовым импульсом. В данном преобразователе в процессе работы наиболее сильно нагревается индуктор и наименее нагревается якорь. Показано, что в ЛИИЭП со схемой питания индуктора, формирующей апериодический токовый импульс возбуждения с подключением добавочного емкостного накопителя энергии, все электромеханические показатели выше по сравнению с ЛИИЭП со схемой питания индуктора, формирующей колебательнозатухающий токовый импульс возбуждения. Однако в этом ЛИИЭП возрастают превышения температур активных
элементов, особенно сильно – индуктора и снижается КПД |
uk_UA |
dc.description.abstract |
На основі розробленої ланцюгової математичної моделі отримані рекурентні співвідношення для розрахунку взаємопов’язаних електромагнітних, механічних та теплових параметрів лінійного імпульсно-індукційного електромеханічного перетворювача (ЛІІЕП). Показано, що електромеханічні показники ЛІІЕП зі схемою живлення індуктора, яка
формує аперіодичний струмовий імпульс збудження, краще, ніж у ЛІІЕП зі збудженням індуктора однополярним
струмовим імпульсом, але гірше, ніж у ЛІІЕП зі збудженням індуктора коливально-загасаючим струмовим імпульсом.
В цьому перетворювачі у процесі роботи найбільш сильно нагрівається індуктор та найменше нагрівається якір.
Показано, що у ЛІІЕП зі схемою живлення індуктора, яка формує аперіодичний струмовий імпульс збудження із підключенням додаткового ємнісного накопичувача, всі електромеханічні показники вище у порівнянні з ЛІІЕП зі схемою
живлення індуктора, яка формує коливально-загасаючий струмовий імпульс збудження. Однак в цьому ЛІІЕП збільшуються перевищення температур активних елементів, особливо сильно індуктора та відбувається зниження ККД |
uk_UA |
dc.description.abstract |
Purpose. The goal of the paper is to investigate the influence of the
power circuits of the linear pulse-induction electromechanical
converters (LPIEC), which form the current pulse of excitation of
the inductor from the capacitive energy storage (CES), to its electromechanical parameters. Methodology. A circuit mathematical
model of LPIEC was developed, on the basis of which recurrence
relations were obtained for calculating the interrelated electromagnetic, mechanical, and thermal parameters of the LPIEC. This
model makes it possible to calculate the LPIEC parameters for
various power circuits, the inductor of which is excited by the CES.
Results. It is established that electromechanical LPEC parameters
with power circuit forming an aperiodic current excitation pulse of
an inductor are better than in LPIEC with excitation of an inductor
by an unipolar current pulse, but worse than in LPIEC with excitation of an inductor by a vibrationally damped current pulse. In this
converter, during operation, the inductor is heated most, and the
armature is heated least. It is established that in LPIEC with power
circuit that forms an aperiodic current pulse of excitation of an
inductor with the connection of an additional CES, all electromechanical parameters are higher in comparison with the LPIEC with
a power circuit that forms a vibrationally damped current excitation
pulse of the inductor. However, in this LPIEC the excess of the
temperatures of the active elements increases, especially strongly in
the inductor, and the efficiency of the converter decreases. Originality. For the first time, the LPIEC has been investigated using the
power circuit that forms an aperiodic current pulse of excitation of
an inductor with the connection of an additional CES. It is established that in this LPIEC all electromechanical parameters are
higher than for LPIEC with power circuits forming an unipolar or
oscillating-damped current excitation pulse of the inductor. Practical value. In the LPIEC with power circuit that forms an aperiodic
current pulse of excitation of the inductor with the connection of an
additional CES, the electromechanical LPIEC parameters increase.
This increases the temperature rise of the inductor, and the temperature rise of the armature decreases. The effectiveness of this
LPIEC is also reduced. |
uk_UA |
dc.language.iso |
ru |
uk_UA |
dc.publisher |
Інститут технічних проблем магнетизму НАН України |
uk_UA |
dc.relation.ispartof |
Електротехніка і електромеханіка |
|
dc.subject |
Електричні машини та апарати |
uk_UA |
dc.title |
Исследование линейного импульсно-индукционного электромеханического преобразователя при различных схемах питания индуктора |
uk_UA |
dc.title.alternative |
Investigation of a linear pulse-induction electromechanical converter with different inductor power supply circuits |
uk_UA |
dc.type |
Article |
uk_UA |
dc.status |
published earlier |
uk_UA |
dc.identifier.udc |
621.313:536.2.24:539.2 |
|