Развитие теории мгновенной мощности трехфазной сети в условиях сетецентризма

Репозиторій DSpace/Manakin

Показати простий запис статті

dc.contributor.author Сокол, Е.И
dc.contributor.author Сиротин, Ю.А.
dc.contributor.author Иерусалимова, Т.С.
dc.contributor.author Гриб, О.Г.
dc.contributor.author Швец, С.В.
dc.contributor.author Гапон, Д.А
dc.date.accessioned 2019-02-15T10:16:24Z
dc.date.available 2019-02-15T10:16:24Z
dc.date.issued 2017
dc.identifier.citation Развитие теории мгновенной мощности трехфазной сети в условиях сетецентризма / Е.И. Сокол, Ю.А. Сиротин, Т.С. Иерусалимова, О.Г. Гриб, С.В. Швец, Д.А. Гапон // Електротехніка і електромеханіка. — 2017. — № 4. — С. 61-65. — Бібліогр.: 9 назв. — рос. uk_UA
dc.identifier.issn 2074-272X
dc.identifier.other DOI: https://doi.org/10.20998/2074-272X.2017.4.10
dc.identifier.uri http://dspace.nbuv.gov.ua/handle/123456789/147582
dc.description.abstract Обеспечение сетецентрического подхода к режиму управления трехфазной сетью и оценка сбалансированности режима сети с учетом влияния мгновенной мощности на величину потерь даст возможность исключить появление нулевой последовательности и, тем самым, повысить качество электроэнергии uk_UA
dc.description.abstract Забезпечення мережецентричного підходу до режиму управління трифазною мережею і оцінка збалансованості режиму мережі з урахуванням впливу миттєвої потужності на величину втрат дасть можливість виключити появу нульової послідовності і, тим самим, підвищити якість електроенергії. uk_UA
dc.description.abstract Purpose. Information technologies allow multidimensional analysis of information about the state of the power system in a single information space in terms of providing network-centric approach to control and use of unmanned aerial vehicles as tools for condition monitoring of three-phase network. Methodology. The idea of energy processes in three independent (rather than four dependent) curves vector-functions with values in the arithmetic threedimensional space adequately for both 4-wire and 3–wire circuits. The presence of zero sequence current structural (and mathematically) features a 4-wire scheme of energy from a 3-wire circuit. The zero sequence voltage caused by the displacement of the zero voltage phases. Offset zero in the calculations can be taken into account by appropriate selection of the reference voltages. Both of these energetic phenomena with common methodical positions are described in the framework of the general mathematical model, in which a significant role is played by the ort zero sequence. Results. Vector approach with a unified voice allows us to obtain and analyze new energy characteristics for 4–wire and 3–wire circuits in sinusoidal and non-sinusoidal mode, both in temporal and frequency domain. Originality. Symmetric sinusoidal mode is balanced, even with non-zero reactive power. The converse is not true. The mode can be balanced and unbalanced load. The mode can be balanced and unbalanced voltage. Practical value. Assessing balance in network mode and the impact of instantaneous power on the magnitude of the losses, will allow to avoid the appearance of zero sequence and, thus, to improve the quality of electricity uk_UA
dc.language.iso ru uk_UA
dc.publisher Інститут технічних проблем магнетизму НАН України uk_UA
dc.relation.ispartof Електротехніка і електромеханіка
dc.subject Електричні станції, мережі і системи uk_UA
dc.title Развитие теории мгновенной мощности трехфазной сети в условиях сетецентризма uk_UA
dc.title.alternative The development of the theory of instantaneous power of three-phase network in terms of network centrism uk_UA
dc.type Article uk_UA
dc.status published earlier uk_UA
dc.identifier.udc 621.311