Перегляд за автором "Romanovsky, S.K."

Сортувати за: Порядок: Результатів:

  • Pomatsalyuk, R.I.; Romanovsky, S.K.; Shevchenko, V.A.; Tenishev, A.Eh.; Titov, V.Yu.; Titov, D.V.; Uvarov, V.L.; Zakharchenko, A.A. (Вопросы атомной науки и техники, 2019)
    Continuous monitoring of critical parameters of an industrial electron accelerator provides quality of product processing. For that purpose, the methods of contact-free diagnostics of processing regime are developed. One ...
  • Akchurin, Y.I.; Boriskin, V.N.; Momot, V.A.; Ivahnenko, A.V.; Ivahnenko, M.V.; Nescheret, S.F.; Romanovsky, S.K.; Savchenko, A.N.; Sarvilov, A.A.; Shelepko, S.V.; Tatanov, V.I.; Tsebenko, G.N.; Yeran, L.V. (Вопросы атомной науки и техники, 2007)
    NESTOR (New-generation Electron STOrage Ring) consisting of electron storage ring, injector and linac with beam energy 60-100 MeV was developed for X-rays source creating based on the use Compton laser radiation scattering ...
  • Romanovsky, S.K.; Shevchenko, V.A.; Tenishev, A.Eh.; Titov, V.Yu.; Titov, D.V.; Uvarov, V.L. (Вопросы атомной науки и техники, 2017)
    A method has been developed and experimental investigation conducted on time dependence of intensity of the cathodoluminescence (CL) induced in technical dielectric materials by high-energy pulse electron beam. At a LU-10 ...
  • Bakai, A.S.; Boriskin, V.N.; Bratchenko, M.I.; Biller, E.Z.; Bytenko, P.A.; Bocharov, V.A.; Vereshchaka, V.N.; Dovbnya, A.N.; Duldya, S.V.; Gorenko, Yu.V.; Kovalev, G.G.; Momot, V.A.; Repihov, O.A.; Romanovsky, S.K.; Savchenko, A.N.; Seleznev, V.V.; Solodovnikov, V.I.; Titov, V.I.; Torgovkin, A.V.; Handak, V.V.; Shelepko, S.V.; Tcebenko, G.N. (Вопросы атомной науки и техники, 2013)
    The design of the Supercritical Water Convection Loop with an irradiation chamber is described [1]. The plant makes possible to carry out simulation corrosion tests of potential structural materials for Generation IV ...
  • Pomatsalyuk, R.I.; Romanovsky, S.K.; Shevchenko, V.A.; Tenishev, A.Eh.; Titarenko, Yu.A.; Titov, D.V.; Titov, V.Yu.; Uvarov, V.L. (Вопросы атомной науки и техники, 2021)
    Radiation-technological processes on the basis of electron accelerators, in particular, sterilization of medical devices, are regulated by international standards. The distribution of the electron flux density and absorbed ...
  • Boriskin, V.N.; Romanovsky, S.K.; Momot, V.A.; Titarenko, Yu.A.; Titov, D.V.; Uvarov, V.L.; Shevchenko, V.A.; Shelepko, S.V. (Вопросы атомной науки и техники, 2015)
    A method of remote on-line control of the temperature of objects heated by an electron beam has been developed and researched. The method is based on analysis of object radiation in optical and infrared ranges and determination ...
  • Bakai, A.S.; Boriskin, V.N.; Bratchenko, M.I.; Dovbnya, A.N.; Dyuldya, S.V.; Gorenko, Yu.V.; Momot, V.A.; Romanovsky, S.K.; Savchenko, A.N.; Solodovnikov, V.I.; Titov, V.Yu.; Shelepko, S.V.; Tcebenko, G.N. (Вопросы атомной науки и техники, 2017)
    The specially designed in the NSC KIPT Supercritical Water Convection Loop (SCWCL) with an irradiation chamber coupled to an electron accelerator LPE-10 gives an opportunity for corrosion and mechanical tests of materials ...
  • Mats, V.O.; Romanovsky, S.K.; Titarenko, Yu.O.; Titov, V.Yu.; Tur, Yu.D. (Вопросы атомной науки и техники, 2021)
    A device designed for continuous remote control of the parameters of the incandescent circuit of the electronic gun of the accelerator LU-10 has been developed. The created device allows to measure with galvanic isolation ...
  • Boriskin, V.N.; Momot, V.A.; Romanovsky, S.K.; Savchenko, A.N.; Solodovnikov, V.I.; Shelepko, S.V. (Вопросы атомной науки и техники, 2014)
    The Convection Loop control system for research of water parameters in supercritical and "nearby" critical state is considered. Results of experiments are presented.
  • Pomatsalyuk, R.I.; Romanovsky, S.K.; Shevchenko, V.A.; Tenishev, A.Eh.; Titov, D.V.; Uvarov, V.L.; Zakharchenko, A.A.; Zhyglo, V.Ph. (Вопросы атомной науки и техники, 2022)
    Validation of process of medical product sterilization includes absorbed dose mapping in a phantom made of material representative of the object to be processed. Commonly, such measurements are carried out using the ...
  • Beloglazov, V.I.; Tur, Yu.D.; Titarenko, Yu.A.; Filippov, A.V.; Romanovsky, S.K. (Вопросы атомной науки и техники, 2015)
    In order to ensure long-term stability of beam parameters of linear accelerators is working on stabilizing the excitation of high-power systems. At this stage the solution of the problem, developed and applied in practice ...
  • Boriskin, V.N.; Zakutin, V.V.; Reshetniak, N.G.; Romanovsky, S.K.; Tenishev, A.Eh.; Titov, V.J.; Chertishev, I.A.; Shevchenko, V.A.; Shlyakhov, I.N.; Uvarov, V.L. (Вопросы атомной науки и техники, 2014)
    The system for visual monitoring of the electron beam was developed and implemented. The technique is based on registration of optical radiation, which is generated under object-beam interaction. The system comprises ...
  • Romanovsky, S.K.; Uvarov, V.L. (Вопросы атомной науки и техники, 2018)
    Main features of cathodoluminescence (CL) of amorphous dielectrics exposed to pulsed beam of accelerated electrons are described. On the basis of a simplified two-level model of electron traps in the prohibited zone, it ...