Наукова електронна бібліотека
періодичних видань НАН України

Erosion, permeation and outgassing performances of tin coating under/after hydrogen plasma iffadiation

Репозиторій DSpace/Manakin

Показати простий запис статті

dc.contributor.author Glazunov, G.P.
dc.contributor.author Volkov, E.D.
dc.contributor.author Veremeyenko, V.P.
dc.contributor.author Kosik, N.A.
dc.contributor.author Kutsyn, Al.A.
dc.contributor.author Langner, J.
dc.contributor.author Langner, E.
dc.contributor.author Mironov, Yu.K.
dc.contributor.author Nazarov, N.I.
dc.contributor.author Piekoszewski, J.
dc.contributor.author Sadowski, M.
dc.contributor.author Stanislawski, J.
dc.contributor.author Tereshin, V.I.
dc.date.accessioned 2015-03-18T19:20:18Z
dc.date.available 2015-03-18T19:20:18Z
dc.date.issued 2000
dc.identifier.citation Erosion, permeation and outgassing performances of tin coating under/after hydrogen plasma iffadiation / G.P. Glazunov, E.D. Volkov, V.P. Veremeyenko, N.A. Kosik, Al.A. Kutsyn, J. Langner, E. Langner, Yu.K. Mironov, N.I. Nazarov, J. Piekoszewski, M. Sadowski, J. Stanislawski, V.I. Tereshin // Вопросы атомной науки и техники. — 2000. — № 6. — С. 155-159. — Бібліогр.: 18 назв. — англ. uk_UA
dc.identifier.issn 1562-6016
dc.identifier.uri http://dspace.nbuv.gov.ua/handle/123456789/78559
dc.description.abstract An erosion behavior of TiN-coated stainless-steel (SS) surfaces was investigated during biased-limiter experiments within the Uragan-3M torsatron and during simulation experiments, which were performed with plasma-accelerator and glow-discharge (GD) plasmas. For a TiN-coated SS head-plate of a limiter the arc ignition probability was found to be lower than 10-4 per plasma pulse. Possible physical mechanisms of this effect had been discussed. Within special vacuum stands, using thermal-desorption and mass-spectrometry methods, there were performed measurements of an outgassing rate and hydrogen permeability of TiNcoatings. The negligible outgassing from TiN-coated SS samples, during their heating up to 473 K, was observed after a cleaning procedure with a molecular hydrogen inflow under pressure of about 10-4 Torr, on contrary to the considerable increase of (q) rate for the irradiated samples. Measured values of the TiN-film hydrogen permeability were several times lower, and activation energy of the hydrogen permeation was considerably lower than that for the SS films (15 kJ/mole instead of 19.9 kJ/mole). The use of TiN-coated SS and diffusion membranes, for the reduction of the erosion, recycling, and hydrogen isotope inventory control, as well as for improvement of vacuum conditions, has been considered. uk_UA
dc.language.iso en uk_UA
dc.publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України uk_UA
dc.relation.ispartof Вопросы атомной науки и техники
dc.subject Low temperature plasma and plasma technologies uk_UA
dc.title Erosion, permeation and outgassing performances of tin coating under/after hydrogen plasma iffadiation uk_UA
dc.type Article uk_UA
dc.status published earlier uk_UA
dc.identifier.udc 533.9


Файли у цій статті

Ця стаття з'являється у наступних колекціях

Показати простий запис статті

Пошук


Розширений пошук

Перегляд

Мій обліковий запис