Наукова електронна бібліотека
періодичних видань НАН України

Advanced research of the impact of rotor bars anisotropic conductivity on starting torque of an induction motor with a die-cast copper cage

Репозиторій DSpace/Manakin

Показати простий запис статті

dc.contributor.author Chuvashev, V.A.
dc.contributor.author Varenyk, Ye.A.
dc.contributor.author Papazov, Yu.N.
dc.contributor.author Chuvankov, V.Yu.
dc.contributor.author Zheleznyakov, A.V.
dc.contributor.author Olenchenko, A.V.
dc.contributor.author Moukhametchine, N.A.
dc.date.accessioned 2018-10-14T12:23:55Z
dc.date.available 2018-10-14T12:23:55Z
dc.date.issued 2006
dc.identifier.citation Advanced research of the impact of rotor bars anisotropic conductivity on starting torque of an induction motor with a die-cast copper cage / V.A. Chuvashev, Ye.A. Varenyk, Yu.N. Papazov, V.Yu. Chuvankov, A.V. Zheleznyakov, A.V. Olenchenko, N.A. Moukhametchine // Електротехніка і електромеханіка. — 2006. — № 3. — С. 12-14. — Бібліогр.: 4 назв. — англ. uk_UA
dc.identifier.issn 2074-272X
dc.identifier.uri http://dspace.nbuv.gov.ua/handle/123456789/142707
dc.description.abstract Изложены результаты исследований влияния анизотропии проводимости стержней ротора на пусковой момент асинхронного двигателя, стендовых и эксплуатационных испытаний взрывозащищенного двигателя типа 2ЭКВ3,5-210 мощностью 210 кВт с литой анизотропной медной обмоткой ротора. uk_UA
dc.description.abstract Викладено результати досліджень впливу анізотропії провідності стрижнів ротора на пусковий момент асинхронного двигуна, стендових і експлуатаційних іспитів вибухозахищеного двигуна типу 2ЕКВ3,5-210 потужністю 210 квт із литою анізотропною мідною обмоткою ротора. uk_UA
dc.description.abstract The paper deals with an optimal design of an induction motor with a die-cast copper cage rotor characterized by an anisotropic layer in the upper part of the rotor bars. 1D FEM optimization of an explosion-proof induction motor with a die-cast copper rotor with overall parameters of a commercial induction motor with a die-cast aluminum rotor (180 kW, 1140 V, 1500 rpm) is made with the help of numeric computations. In the paper, the design features and experimental results are given. It is shown that induction motors with a special “starting” layer placed in the upper part the diecast copper rotor bar have maximum value of starting torque for relative conductivity factors ranging from 0.3 to 0.5. The basic performance data obtained in both bench and service tests of a prototype 210kW induction motor are in close agreement with analytical data. uk_UA
dc.language.iso en uk_UA
dc.publisher Інститут технічних проблем магнетизму НАН України uk_UA
dc.relation.ispartof Електротехніка і електромеханіка
dc.subject Електричні машини та апарати uk_UA
dc.title Advanced research of the impact of rotor bars anisotropic conductivity on starting torque of an induction motor with a die-cast copper cage uk_UA
dc.type Article uk_UA
dc.status published earlier uk_UA
dc.identifier.udc 621.313.333-213.34