Перегляд за автором "Maznichenko, S.M."

Сортувати за: Порядок: Результатів:

  • Moiseenko, V.E.; Tarasov, I.K.; Tarasov, M.I.; Sitnikov, D.A.; Korovin, V.B.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Zhezhera, A.I.; Pavlichenko, R.O.; Zamanov, N.V.; Kulaga, A.Ye.; Shapoval, A.N.; Lytova, M.A.; Maznichenko, S.M.; Solodovchenko, S.I.; Shtan', A.F. (Вопросы атомной науки и техники, 2014)
    The possibilities of stimulation and complete suppression of the runaway electrons flow in the experiments at Uragan-2M setup were investigated. The flow stimulation was carried out by producing additional free charged ...
  • Kozulya, M.M.; Kramskoy, E.D.; Korovin, V.B.; Yevsyukov, A.V.; Lozin, A.V.; Kasilov, A.A.; Grigor’eva, L.I.; Kulaga, A.E.; Maznichenko, S.M.; Mironov, Yu.K.; Romanov, V.S.; Chechkin, V.V. (Вопросы атомной науки и техники, 2015)
    Deficient shot-to-shot stability of Uragan-3M discharges makes difficult to reproduce experimental results over the period of experimental session. An efficient way of reducing difference between shots is creation of initial ...
  • Berezhnyj, V.L.; Ocheretenko, V.L.; Pinos, I.B.; Skibenko, A.I.; Prokopenko, A.V.; Larin, Yu.V.; Maznichenko, S.M.; Sitnikov, D.A.; Tarasov, M.I. (Вопросы атомной науки и техники, 2009)
    To study successfully the conditions for production and heating of the plasma, its dynamics in the process of an RF discharge in the torsatron U-2M, a multichannel system for microwave diagnostics is suggested. To obtain ...
  • Komarov, A.D.; Chmyga, A.A.; Chechkin, V.V.; Grigor’eva, L.I.; Deshko, G.N.; Kozachek, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Maznichenko, S.M.; Mironov, Yu.K.; Romanov, V.S.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2016)
    First estimations of plasma electric potential and density in URAGAN -2M (U-2M) torsatron were done by the Heavy Ion Beam Probing Diagnostic (HIBP). The estimated plasma potential has the negative potential value of -(80…195) ...
  • Beletskii, A.A.; Berezhnyj, V.L.; Burchenko, P.Ya.; Chechkin, V.V.; Chernyshenko, V.Ya.; Grigor’eva, L.I.; Gubarev, S.P.; Konovalov, V.G.; Kulaga, A.E.; Kurilo, D.V.; Lesnyakov, G.G.; Losin, A.V.; Maznichenko, S.M.; Mironov, Yu.K.; Moiseenko, V.E.; Ozherel’ev, F.I.; Opaleva, G.P.; Pashnev, V.K.; Pavlichenko, O.S.; Prokopenko, A.V.; Romanov, V.S.; Sergeev, Yu.F.; Skibenko, A.I.; Shapoval, A.N.; Shtan, A.F.; Shvets, O.M.; Solodovchenko, S.I.; Sorokovoy, Ye.L.; Taran, V.S.; Tarasov, I.K.; Tereshin, V.I.; Tsybenko, S.A.; Voitsenya, V.S.; Volkov, E.D.; Zolototrubova, M.I. (Вопросы атомной науки и техники, 2008)
    The results of experimental investigation on the vacuum magnetic surfaces in the l=2 torsatron with an additional toroidal field Uragan-2M at wide varying operation parameters are presented. Also the first results on the ...
  • Voitsenya, V.S.; Konovalov, V.G.; Ryzhkov, I.V.; Solodovchenko, S.I.; Shtan’, A.F.; Shapoval, A.N.; Maznichenko, S.M. (Вопросы атомной науки и техники, 2018)
    The results are presented on a postmortem analysis of the mirror-like SS samples and two glass samples exposed in the Uragan-2M (U-2M) vacuum chamber during experimental campaigns in 2015 and 2016 years. The examination ...
  • Glazunov, G.P.; Baron, D.I.; Bondarenko, M.N.; Burchenko, P.Ya.; Chechkin, V.V.; Chernyshenko, V.Ya.; Grigor’eva, L.I.; Konovalov, V.G.; Konotopskiy, A.L.; Kotenko, V.G.; Lozin, A.V.; Maznichenko, S.M.; Moiseenko, V.E.; Pashnev, V.K.; Ponomarenko, N.P.; Solodovchenko, S.I.; Sorokovoy, Ye.L.; Shapoval, A.V.; Tereshin, V.I.; Voitsenya, V.S. (2010)
    The work describes the design of a multifunctional B4C-limiter, and reports preliminary results from experimental study of the limiter operated at steady-state and pulsed RF discharge cleaning regimes in the Uragan-2M torsatron.
  • Glazunov, G.P.; Konotopskiy, A.L.; Vinogradov, D.M.; Bondarenko, M.N.; Maznichenko, S.M.; Svynarenko, O.P. (Вопросы атомной науки и техники, 2017)
    The developed models of ultra-pure hydrogen generators had been designed, produced and tested. The influence of membrane temperature and form, position in the flame, installation of additional screens etc. were investigated. ...
  • Baron, D.I.; Chernyshenko, V.Ya.; Korovin, V.B.; Kramskoy, E.D.; Maznichenko, S.M.; Shtan, A.F.; Solodovchenko, S.I. (Вопросы атомной науки и техники, 2013)
    An experiment on chamber RF cleaning for 12 hours a day during 2 weeks with the subsequent vacuum pumping out was carried out. The plasma was produced by the UHF generator with the frequency of 2.4 GHz. Afterwards, the VHF ...
  • Gubarev, S.P.; Ermakov, E.B.; Lesnyakov, G.G.; Maznichenko, S.M.; Opaleva, G.P.; Ozherel’ev, F.I.; Taran, V.S.; Tereshin, V.I.; Zolototrubova, M.I. (Вопросы атомной науки и техники, 2009)
    Created hardware - software complex, intended for scan controlling with luminescent rod of magnetic surfaces in the poloidal cross-section of the torus (in the toroidal vacuum chamber), and investigating the structure of ...
  • Sitnikov, D.A.; Berezhnyj, V.L.; Larin, Y.V.; Maznichenko, S.M.; Ocheretenko, V.L.; Pinos, I.B.; Prokopenko, A.V.; Skibenko, A.I.; Tarasov, M.I. (Вопросы атомной науки и техники, 2008)
    The construction of microwave sections together with results of loss calculation in the microwave lines for different frequencies are presented. The construction of microwave lead-ins is also described. The whole system ...
  • Chechkin, V.V.; Pankratov, I.M.; Grigor’eva, L.I.; Beletskii, А.А.; Kasilov, A.A.; Burchenko, P.Ya.; Lozin, А.V.; Tsybenko, S.А.; Slavnyj, А.S.; Litvinov, A.P.; Kulaga, А.Ye.; Pavlichenko, R.O.; Zamanov, N.V.; Mironov, Yu.K.; Romanov, V.S.; Pashnev, V.K.; Maznichenko, S.M.; Volkov, Ye.D. (Вопросы атомной науки и техники, 2012)
    In the l=3 Uragan-3M torsatron a hydrogen plasma with the density ¬ne ~ 2×10¹² cm⁻³ is produced and heated by RF fields in the ω ≤ ωсi range of frequencies with using a frame-like antenna. Time variations are considered ...
  • Zhezhera, A.I.; Chmyga, A.A.; Deshko, G.N.; Krupnik, L.I.; Kozachek, A.S.; Komarov, A.D.; Khrebtov, S.M.; Maznichenko, S.M.; Tashchev, Yu.I.; Lesnyakov, G.G.; Tarasov, I.K.; Perfilov, S.V. (Вопросы атомной науки и техники, 2015)
    The Heavy Ion Beam Probing (HIBP) diagnostic system has been installed and operates now on the Uragan-2M torsatron for the first time in Ukraine. The cesium ion beam with energy range of 17…120 keV and ion current of 10…150 ...
  • Glazunov, G.P.; Baron, D.I.; Bondarenko, M.N.; Chernyshenko, V.Ya.; Konotopskiy, A.L.; Listopad, V.M.; Maznichenko, S.M.; Pashnev, V.K. (Вопросы атомной науки и техники, 2012)
    Using the thermal desorption method the investigations were carried out of stainless steel probe outgassing rate in a vacuum and estimation of the number of monolayers on its surface in the Uragan-2M torsatron in situ. The ...
  • Lozin, A.V.; Moiseenko, V.E.; Grigor’eva, L.I.; Kozulya, M.M.; Krasyuk, A.Yu.; Kulaga, A.E.; Kramskoy, E.D.; Lyssoivan, A.I.; Maznichenko, S.M.; Mironov, Yu.K.; Pavlichenko, R.O.; Zamanov, N.V.; Romanov, V.S.; Chernyshenko, V.Ya.; Chechkin, V.V. (Вопросы атомной науки и техники, 2013)
    Unshielded THT antenna is successfully used: (i) for heating of plasma prepared by the frame antenna pulse, (ii) for making an initial plasma with low density ~10¹⁰ cm⁻³ for further frame antenna operation, (iii) for ...