Перегляд за автором "Dronov, R.N."

Сортувати за: Порядок: Результатів:

  • Vereshchaka, V.N.; Dovbnya, A.N.; Dronov, R.N.; Myakushko, L.K.; Reprintsev, L.V.; Savchenko, A.N.; Sarvilov, A.A.; Tatanov, V.I.; Shevchenko, V.A.; Shendrik, V.A.; Boriskin, V.N. (Вопросы атомной науки и техники, 2014)
    Control of beam parameters is important for maintenance of linac operating conditions, as well as, for securing a high-speed protection of exit channel components against the beam damage. For this purpose the beam current, ...
  • Dronov, R.N.; Reprintsev, L.V.; Tatanov, V.I. (Вопросы атомной науки и техники, 2020)
    To increase the reliability of operation and simplify the precise tuning of the beam it is proposed to upgrade the output part of the accelerator “EPOS” NSC KIPT that operates in the range of electron energies 25…35 MeV ...
  • Guk, I.S.; Dronov, R.N.; Deiev, O.S.; Shramenko, B.I. (Вопросы атомной науки и техники, 2021)
    The process of “Glucose ¹¹C” pharmaceutical production by means of a photonuclear reaction ¹²C(γ, n)¹¹C is considered. The parameters of bremsstrahlung and electron beam scattered in the converter are investigated and ...
  • Voronko, V.O.; Dronov, R.N.; Shramenko, B.I.; Beloziorov, І.V.; Girka, I.O. (Вопросы атомной науки и техники, 2020)
    The creation of a PET center in the Kharkov region is proposed. This is facilitated by the transfer of the cyclotron by the Julich Research Center (Germany) to Kharkiv, which will ensure the development of the diagnostic ...
  • Antipov, K.I.; Ayzatsky, M.I.; Akchurin, Yu.I.; Gurin, V.A.; Boriskin, V.N.; Beloglasov, V.I.; Biller, E.Z.; Demidov, N.V.; Dovbnya, A.N.; Dronov, R.N.; Khodak, I.V.; Kosoy, A.I.; Kushnir, V.A.; Momot, V.A.; Myakushko, L.K.; Mytrochenko, V.V.; Nikitina, T.F.; Opanasenko, A.N.; Perezhogin, S.A.; Pugachev, G.D.; Repikhov, O.A.; Reprintzev, L.V.; Shendrik, V.A.; Stepin, D.L.; Tarasov, G.E.; Tur, Yu.D.; Zhiglo, V.F. (Вопросы атомной науки и техники, 2004)
    The S-band electron linac has been designed at NSC KIPT to cover an energy range from 30 to 100 MeV. The linac consists of the injector based on evanescent oscillations and the two four-meter long piecewise homogeneous ...
  • Bakai, A.S.; Boriskin, V.N.; Bratchenko, M.I.; Dronov, R.N.; Dyuldya, S.V.; Gorenko, Yu.V.; Shelepko, S.V. (Вопросы атомной науки и техники, 2019)
    To study experimentally the stress enhanced corrosion of structural materials in a water coolant flow under electron irradiation, a novel design of the target irradiation cell was developed. The stress application scheme ...